Use este identificador para citar ou linkar para este item: https://repositorio.ufrn.br/jspui/handle/123456789/23800
Título: Biomechanical evaluation of internal and external hexagon platform switched implant-abutment connections: an in vitro laboratory and three-dimensional finite element analysis
Autor(es): Freitas Junior, Amilcar Chagas
Rocha, Eduardo P.
Bonfante, Estevam A.
Almeida, Erika Oliveira de
Anchieta, Rodolfo Bruniera
Martini, Ana P.
Assunção, Wirley G.
Silva, Nelson R. F. A.
Coelho, Paulo G.
Palavras-chave: Dental implants;Platform switching;Biomechanics;Reliability;Finite element analysis
Data do documento: 2012
Editor: ELSEVIER
Referência: FREITAS JUNIOR, Amilcar C. et al. Biomechanical Evaluation of Internal and External Hexagon Platform Switched Implant-Abutment Connections: An In Vitro Laboratory and Three-Dimensional Finite Element Analysis. Dental Materials, v. 7, n. 10, p. 1-8, 2012.
Resumo: Objectives The aim of this study was to assess the effect of abutment's diameter shifting on reliability and stress distribution within the implant-abutment connection for internal and external hexagon implants. The postulated hypothesis was that platform-switched implants would result in increased stress concentration within the implant-abutment connection, leading to the systems’ lower reliability. Methods Eighty-four implants were divided in four groups (n = 21): REG-EH and SWT-EH (regular and switched-platform implants with external connection, respectively); REG-IH and SWT-IH (regular and switched-platform implants with internal connection, respectively). The corresponding abutments were screwed to the implants and standardized maxillary central incisor metal crowns were cemented and subjected to step-stress accelerated life testing. Use-level probability Weibull curves and reliability were calculated. Four finite element models reproducing the characteristics of specimens used in laboratory testing were created. The models were full constrained on the bottom and lateral surface of the cylinder of acrylic resin and one 30° off-axis load (300 N) was applied on the lingual side of the crown (close to the incisal edge) in order to evaluate the stress distribution (svM) within the implant-abutment complex. Results The Beta values for groups SWT-EH (1.31), REG-EH (1.55), SWT-IH (1.83) and REG-IH (1.82) indicated that fatigue accelerated the failure of all groups. The higher levels of σvM within the implant-abutment connection observed for platform-switched implants (groups SWT-EH and SWT-IH) were in agreement with the lower reliability observed for the external hex implants, but not for the internal hex implants. The reliability 90% confidence intervals (50,000 cycles at 300 N) were 0.53(0.33–0.70), 0.93(0.80–0.97), 0.99(0.93–0.99) and 0.99(0.99–1.00), for the SWT-EH, REG-EH, SWT-IH, and REH-IH, respectively. Significance The postulated hypothesis was partially accepted. The higher levels of stress observed within implant-abutment connection when reducing abutment diameter (cross-sectional area) resulted in lower reliability for external hex implants, but not for internal hex implants.
URI: https://repositorio.ufrn.br/jspui/handle/123456789/23800
Aparece nas coleções:CCS - DOD - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Biomechanical Evaluation of Internal_2012.pdfhttp://www.sciencedirect.com/science/article/pii/S01095641120016501.64 MBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.