Use este identificador para citar ou linkar para este item: https://repositorio.ufrn.br/handle/123456789/24309
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorOliveira, K. P.-
dc.contributor.authorMoraes, P. H.-
dc.contributor.authorSilva, José Sandro Pereira da-
dc.contributor.authorQueiroz, W. F.-
dc.contributor.authorGermano, Adriano Rocha-
dc.date.accessioned2017-11-20T17:00:36Z-
dc.date.available2017-11-20T17:00:36Z-
dc.date.issued2014-
dc.identifier.citationOLIVEIRA, K. P. et al. In vitro mechanical assessment of 2.0-mm system three-dimensional miniplates in anterior mandibular fractures. International Journal of Oral and Maxillofacial Surgery, v. 43, n. 5, p. 564-571, 2014.pt_BR
dc.identifier.urihttps://repositorio.ufrn.br/jspui/handle/123456789/24309-
dc.languageengpt_BR
dc.publisherELSEVIERpt_BR
dc.subjectInternal fracture fixationpt_BR
dc.subjectMandibular fracturespt_BR
dc.subjectBiomaterialpt_BR
dc.subjectBiomechanicspt_BR
dc.subjectTraumapt_BR
dc.titleIn vitro mechanical assessment of 2.0-mm system three-dimensional miniplates in anterior mandibular fracturespt_BR
dc.typearticlept_BR
dc.identifier.doihttps://doi.org/10.1016/j.ijom.2013.10.008-
dc.description.resumoThis study constituted a comparative assessment of the mechanical resistance of square and rectangular 2.0-mm system three-dimensional miniplates as compared to the standard configuration using two straight miniplates. 90 polyurethane replica mandibles were used for the mechanical trials. Groups 1, 2, and 3 simulated complete symphyseal fractures characterized by linear separation of the central incisors; groups 4, 5, and 6 simulated parasymphyseal fractures with an oblique configuration. Groups 1 and 4 represented the standard method with two straight miniplates set parallel to one another. Square miniplates were used in groups 2 and 5, and rectangular miniplates in groups 3 and 6. A universal testing machine set to a velocity of 10mm/min and delivering a vertical linear load to the first left molar was used to test each group. Maximum load values and load values with pre-established dislocation of 5mm were obtained and submitted to statistical analysis using a calculated reliability interval of 95%. The mechanical performances of the devices were similar, except in the case of rectangular plates used in the parasymphyseal fractures. The innovative fixation methods used showed significantly better results in the case of symphyseal fractures.pt_BR
Aparece nas coleções:CCS - DOD - Artigos publicados em periódicos

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.