Navegando por Autor "Fernandes, Lenita da Silva Lucio"
Agora exibindo 1 - 4 de 4
- Resultados por página
- Opções de Ordenação
Dissertação Controle feedback de nível baseado em sensor de imagem aplicado ao equipamento misturador-decantador à inversão de fases (MDIF®)(Universidade Federal do Rio Grande do Norte, 2009-09-03) Fernandes, Lenita da Silva Lucio; Oliveira, Jackson Araújo de; Paulo, João Bosco de Araújo; ; http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4787949Y0#Bancas; ; http://lattes.cnpq.br/5058617634570704; ; http://lattes.cnpq.br/3699377096472387; Silva, Fabrício Machado; ; http://lattes.cnpq.br/0221220703324031; Fernandes Júnior, Wilaci Eutrópio; ; http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4701139Z9; Cavalcanti, Anderson Luiz de Oliveira; ; http://lattes.cnpq.br/7224754476792019O tratamento de águas residuais contaminadas com óleo é um assunto de grande interesse prático, principalmente no que se refere às questões ambientais. Um processo bastante relevante que vem sendo estudado no tratamento semi-contínuo de águas contaminadas com óleo é o Misturador-Decantador à Inversão de Fases (MDIF®). Uma variável importante na operação do sistema MDIF® é o nível da interface solvente orgânico/água na seção de separação. O controle deste nível é essencial tanto para evitar o arraste de solvente pela água como para melhorar a eficiência de remoção do óleo pelo solvente. A despeito disso, a medida (em linha) da interface de separação ainda constitui uma tarefa difícil e são poucos os sensores capazes de medir tal interface. No caso de sistemas em escala de bancada, não há sensores de interface com dimensões compatíveis. O presente trabalho teve como objetivo implementar um sistema de controle de nível para a interface de separação (solvente orgânico/água) no equipamento MDIF®. A medida de nível da interface é baseada na aquisição e tratamento de imagens obtidas dinamicamente por uma câmera (webcam). A estratégia de controle foi desen olvida para operar em modo feedback, onde a medida de nível obtida pelo sensor de imagem é comparada ao nível desejado e a ação de controle é tomada sobre uma válvula, seguindo uma lei do tipo PID. Um programa de aquisição de dados e controle foi desenvolvido em Fortran para realizar as seguintes tarefas: aquisição de imagem, identificação da interface solvente orgânico/água, tomada de decisões, envio dos sinais de controle e registro de dados em arquivo. Alguns experimentos em malha aberta foram realizados, onde perturbações aleatórias tipo pulso foram aplicadas na variável de entrada (vazão de saída de água). As respostas do nível de interface permitiram a identificação do processo através de modelos de função de transferência. A partir destes modelos, os parâmetros para o controlador PID foram sintonizados por síntese direta e testes em malha fechada foram realizados. Os resultados preliminares da malha feedback demonstraram que o sensor e a estratégia de controle desenvolvidos neste trabalho foram satisfatórios para controlar o nível da interface solvente orgânico/águaArtigo Development of a system by atomization for the formation of polymeric particles in micro and sub-micro scales(Elsevier, 2014-06-01) Fernandes, Lenita da Silva Lucio; Cellet, Thelma Sley Pacheco; Souza, Maria Bittencourt Dutra de; Sayer, Claudia; Rubira, Adley Forti; Dariva, Claudio; Oliveira, Jackson Araújo deSeveral studies in nanotechnology have demonstrated significant advantages of nanoparticles compared with microparticles. The main reason for this is the higher ratio of surface area per volume, which results in specific characteristics. Such considerations have driven researchers to develop techniques to obtain polymeric nanoparticles with properties that allow application in different areas. The objective of this work is to present a polymerization process by atomization applied to miniemulsion and suspension systems for formation of submicron particles of poly(methyl methacrylate) (PMMA) and polystyrene (PS). Reactions were carried out using the proposed technique and polymeric particles were obtained with size between 40 and 300 nm, according to dynamic light scattering (DLS) analysis, and with spherical morphological characteristics, according to the results of scanning electron microscopy (SEM) and transmission electron microscopy (TEM)Artigo Gain scheduling adaptive control applied to a particular mixer-settler equipment(Elsevier, 2013-08) Fernandes, Lenita da Silva Lucio; Moraes Filho, Francisco Canindé; Paulo, João Bosco de Araújo; Oliveira, Jackson Araújo deThe mixer-settler based on phase inversion (MSBPI) is a system used for treatment of wastewaters in order to reduce the content of oils and greases from wastewaters produced in oil industry. Its operation principle combines mixing, extraction and separation by decantation in a unique process. In particular, for control purpose, the level of the interface between organic solvent and water, in the separation section, is a critical variable to guarantee performance and security during operation of the MSBPI. In this work, an image-based detector to monitor the organic solvent–water interface level is proposed and a feedback control loop for the process is presented. Initially, a conventional controller (PID) was implemented and, subsequently, a strategy of gain scheduling adaptive control was developed in order to improve the process response in closed-loop. The experimental results showed that the adaptive control presented an efficient performance, even when disturbances of significant magnitude were applied to the processArtigo Nanoprecipitation of particles by atomization of a polymer solution in circulating medium(IOP Science, 2017-10-27) Pereira, André Anderson Costa; Sousa, Elisa Maria Bittencourt Dutra de; Cellet, Thelma S. P.; Fragal, Vanessa H.; Fernandes, Lenita da Silva Lucio; Jesus, Anderson Alles de; Oliveira, Jackson Araújo deThe present study aims to present a system for the production of nano particles of poly (methyl methacrylate) (PMMA) and polycaprolactone (PCL) based on the atomization of polymer solution in anti-solvent medium. In this system, polymer solutions are prepared and atomized in the form of a spray. The droplets generated from atomization come into contact with anti-solvent liquid that causes the precipitation and formation of the polymeric nanoparticles. In this study, experiments using the proposed system were performed under different operating conditions and the particles obtained were analyzed by dynamic light scattering (DLS) and transmission electron microscopy (TEM). The results demonstrated nano and microparticles with a size distribution ranging from 50 to 3000 nm. The morphology and the particle size distribution (PSD) was modified by simple changes in the synthesis as the nature of the polymer, the type of solvent, the atomization pressure and the temperature of the anti-solvent liquid