Use este identificador para citar ou linkar para este item: https://repositorio.ufrn.br/handle/123456789/29808
Título: Wavelet-fuzzy power quality diagnosis system with inference method based on overlap functions: case study in an AC microgrid
Autor(es): Nolasco, Diego H. S.
Costa, Flávio Bezerra
Palmeira, Eduardo Silva
Alves, Denis Keuton
Bedregal, Benjamín Rene Callejas
Rocha, Thiago de Oliveira Alves
Ribeiro, Ricardo Lúcio de Araújo
Silva, Juliano Costa Leal da
Palavras-chave: Power quality;Microgrid;Wavelet packet;Hierarchical fuzzy system;Extended overlap function
Data do documento: 30-Mai-2019
Editor: Elsevier
Referência: NOLASCO, D.H.S.; COSTA, F.B.; PALMEIRA, E.S.; ALVES, D.K.; BEDREGAL, B.R.C.; ROCHA, T.O.A.; RIBEIRO, R.L.A.; SILVA, J.C.L.. Wavelet-fuzzy power quality diagnosis system with inference method based on overlap functions: case study in an ac microgrid. Engineering Applications of Artificial Intelligence, [s.l.], v. 85, p. 284-294, out. 2019. Disponível em: https://www.sciencedirect.com/science/article/abs/pii/S0952197619301241?via%3Dihub#!. Acesso em: 10 ago. 2020. http://dx.doi.org/10.1016/j.engappai.2019.05.016
Resumo: This work proposes a wavelet-fuzzy power quality (PQ) diagnosis method able to evaluate the PQ impact of steady-state (stationary) PQ events in alternating current (AC) microgrids considering the influence of the power level penetration. The proposed method is composed by a wavelet packet-based signal processing to compute the root mean square (RMS) and steady-state PQ indices of measured voltages and currents, providing accurate results even if transient disturbances take place. Thereafter, a cascade-type hierarchical fuzzy system receives the PQ indices and performs the power quality diagnosis to evaluate the impacts of disturbances on electrical system power quality. The proposed method considers subjectivities of several PQ standards simultaneously and applies an adaptive algorithm that allows the evaluation of the PQ diagnosis from the total harmonic distortion of currents considering different levels of power penetration of microgrids. Experimental results obtained from an ac microgrid laboratory setup evaluates the proposed PQ diagnosis method. In addition, the fuzzy system uses a new inference concept based on an extended n-dimensional overlap function
URI: https://repositorio.ufrn.br/jspui/handle/123456789/29808
ISSN: 0952-1976
Aparece nas coleções:CCET - DIMAP - Artigos publicados em periódicos
CT - DEE - Artigos publicados em periódicos
ECT - Artigos publicados em periódicos

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.