Comparison of flow patterns in the radiocephalic arteriovenous fistula throug in vitro and in silico study

dc.contributor.authorMoreira, Ricardo Wagner Costa
dc.contributor.authorOliveira, F. C. M.
dc.contributor.authorBessa, Kleiber Lima de
dc.date.accessioned2023-07-07T19:51:57Z
dc.date.available2023-07-07T19:51:57Z
dc.date.issued2015-11-09
dc.description.resumoThe vascular accesses to hemodialysis patients usually are through arteriovenous fistula (AVF) or synthetic grafts. The analyses of recirculation zones, stagnation points, secondary flow and low and high shear stress are very important points to study for understand the hemodynamic local in arteriovenous fistula. In this work, it was analyzed through computational fluid dynamics the streamlines in AVF and it was compared with the literature results. The flow patterns were visualized under steady and unsteady condition with Reynolds number ranging from 100 up 600. The results obtained from CFD were very similar with the literature results. The flow becomes more chaotic when the Reynolds number increases. Vortex can be seen in anastomosis region, occupying all transversal section of the artery. Thus, the results obtained using CFD look like the results obtained experimentally.pt_BR
dc.identifier.citationMOREIRA, Ricardo Wagner Costa; OLIVEIRA, F. C. M.; BESSA, Kleiber Lima de. COMPARISON OF FLOW PATTERNS IN THE RADIOCEPHALIC ARTERIOVENOUS FISTULA THROUG IN VITRO AND IN SILICO STUDY. Revista de Engenharia Térmica, [S.L.], v. 14, n. 2, p. 07, 31 dez. 2015. Universidade Federal do Parana. http://dx.doi.org/10.5380/reterm.v14i2.62125. Disponível em: https://revistas.ufpr.br/reterm/article/view/62125. Acesso em: 07 jul. 2023.pt_BR
dc.identifier.doihttp://dx.doi.org/10.5380/reterm.v14i2.62125
dc.identifier.urihttps://repositorio.ufrn.br/handle/123456789/53143
dc.languageenpt_BR
dc.publisherRevista de Engenharia Térmicapt_BR
dc.subjectCFDpt_BR
dc.subjectshear stresspt_BR
dc.subjectanastomosespt_BR
dc.titleComparison of flow patterns in the radiocephalic arteriovenous fistula throug in vitro and in silico studypt_BR
dc.typearticlept_BR

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
ComparisonFlowPatterns_Moreira_Etal_2015.pdf
Tamanho:
412.07 KB
Formato:
Adobe Portable Document Format
Nenhuma Miniatura disponível
Baixar

Licença do Pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.45 KB
Formato:
Item-specific license agreed upon to submission
Nenhuma Miniatura disponível
Baixar