Angular dependence of asymmetric magnetoimpedance in exchange biased NiFe/IrMn multilayers

dc.contributor.authorSilva, Ricardo Barreto da Silva
dc.contributor.authorCorrêa, Marcio Assolin
dc.contributor.authorSilva, Edimilson Felix da
dc.contributor.authorMori, Thiago José de Almeida
dc.contributor.authorDella Pace, Rafael Domingues
dc.contributor.authorPinto, Roberta Dutra de Oliveira
dc.contributor.authorViegas, Alexandre Da Cas
dc.contributor.authorBohn, Felipe
dc.contributor.authorSommer, Rubem Luis
dc.date.accessioned2021-11-25T16:15:34Z
dc.date.available2021-11-25T16:15:34Z
dc.date.issued2014-03-11
dc.description.abstractWe investigate the angular dependence of asymmetric magnetoimpedance of NiFe/IrMn multilayers and explore the possibility of tuning the linear region of the magnetoimpedance curves by modifying the angle between the applied external magnetic field and exchange bias field, and probe current frequency. We quantify the sensitivity by calculating the ratio jDZj=jDHj at low magnetic fields as a function of the frequency for samples cut with different orientations and show that considerable values in the linear region around zero field can be reached. The results extend the possibilities for application of exchange biased magnetoimpedance multilayers as probe element for the development and improvement of auto-biased linear magnetic field sensorpt_BR
dc.description.resumoWe investigate the angular dependence of asymmetric magnetoimpedance of NiFe/IrMn multilayers and explore the possibility of tuning the linear region of the magnetoimpedance curves by modifying the angle between the applied external magnetic field and exchange bias field, and probe current frequency. We quantify the sensitivity by calculating the ratio jDZj=jDHj at low magnetic fields as a function of the frequency for samples cut with different orientations and show that considerable values in the linear region around zero field can be reached. The results extend the possibilities for application of exchange biased magnetoimpedance multilayers as probe element for the development and improvement of auto-biased linear magnetic field sensorspt_BR
dc.identifier.citationSILVA, Ricardo Barreto da Silva; CORRÊA, Marcio Assolin; SILVA, Edimilson Felix da; MORI, Thiago José de Almeida; DELLA PACE, Rafael Domingues; PINTO, Roberta Dutra de Oliveira; VIEGAS, Alexandre Da Cas; BOHN, Felipe; SOMMER, Rubem Luis. Angular dependence of asymmetric magnetoimpedance in exchange biased NiFe/IrMn multilayers. Applied Physics Letters, [S.l.], v. 104, n. 10, p. 102405, 10 mar. 2014. AIP Publishing. Disponível em: https://aip.scitation.org/doi/10.1063/1.4867973. Acesso em: 24 mai. 2020. DOI: http://dx.doi.org/10.1063/1.4867973.pt_BR
dc.identifier.issn0003-6951
dc.identifier.issn1077-3118
dc.identifier.urihttps://repositorio.ufrn.br/handle/123456789/45027
dc.languageenpt_BR
dc.publisherAIP Publishing LLCpt_BR
dc.subjectMagnetoimpedância assimétrica de NiFe/IrMnpt_BR
dc.subjectAsymmetric magnetoimpedance of NiFe/IrMnpt_BR
dc.titleAngular dependence of asymmetric magnetoimpedance in exchange biased NiFe/IrMn multilayerspt_BR
dc.typearticlept_BR

Arquivos

Licença do Pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.45 KB
Formato:
Item-specific license agreed upon to submission
Nenhuma Miniatura disponível
Baixar