Please use this identifier to cite or link to this item: https://repositorio.ufrn.br/handle/123456789/29625
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGuerra Neto, Custódio Leopoldino de Brito-
dc.contributor.authorSilva, Marco Aurélio Medeiros da-
dc.contributor.authorAlves Júnior, Clodomiro-
dc.date.accessioned2020-07-14T23:19:36Z-
dc.date.available2020-07-14T23:19:36Z-
dc.date.issued2009-
dc.identifier.citationGUERRA NETO, C. L. B.; SILVA, M. A. M. ; ALVES JUNIOR, C.. Osseointegration evaluation of plasma nitrided titanium implants. Surface Engineering, v. 25, p. 434-439, 2009. Disponível em: https://www.tandfonline.com/doi/abs/10.1179/174329409X389272. Acesso em: 13 jul. 2020. https://doi.org/10.1179/174329409X389272pt_BR
dc.identifier.issn0267-0844-
dc.identifier.urihttps://repositorio.ufrn.br/jspui/handle/123456789/29625-
dc.languageenpt_BR
dc.publisherSurface Engineeringpt_BR
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Brazil*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/br/*
dc.subjectOsseointegrationpt_BR
dc.subjectDental implantspt_BR
dc.subjectSurface modificationspt_BR
dc.subjectPlasma nitridingpt_BR
dc.subjectBiomaterialspt_BR
dc.titleOsseointegration evaluation of plasma nitrided titanium implantspt_BR
dc.typearticlept_BR
dc.identifier.doi10.1179/174329409X389272-
dc.description.resumoThere is a need for new techniques that modify metallic implant surfaces, resulting in good bone response for low density areas. Among the different techniques, plasma nitriding is being applied in biomedicine with excellent results. However, its use in titanium dental implants is very limited owing to high process temperatures (between 700 and 800°C) that result in distortions. In order to solve this problem, the authors used a new plasma method with a hollow cathode discharge configuration. Ti grade II dental implants were nitrided in a 20% N2–H2 atmosphere at a temperature of 450°C, 150 Pa (1·5 mbar), for 1 h and inserted into rabbit tibias to assess osseointegration. The results showed that plasma nitriding caused a significant change in the surface texture of the nitrided implants and greater removal torque than that of the control implantspt_BR
Appears in Collections:CT - DEB - Artigos publicados em periódicos

Files in This Item:
File Description SizeFormat 
OsseointegrationEvaluationOfPlasma_GuerraNeto_2009.pdf805.71 kBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons