Fluid dynamic study in a flexible arteriovenous fistula model

dc.contributor.advisorBessa, Kleiber Lima de
dc.contributor.authorLima, Everton Guedes de
dc.contributor.referees1Rangel, Jonhattan Ferreira
dc.contributor.referees2Santos, Willyam Brito de Almeida
dc.date.accessioned2022-12-14T12:05:09Z
dc.date.available2022-12-14T12:05:09Z
dc.date.issued2022-11-22
dc.description.resumoHemodialysis is the process of extracorporeal dialysis in which the patient's blood is withdrawn through a vascular access (VA) and returned to the patient after passing through a filtration system. Among the most common accesses, the arteriovenous fistula (AVF) is recognized as the best for hemodialysis, providing a continuous and longlasting treatment, however, it has high maturation failure rates. The present work seeks to analyze the pressure field and fluid flow conditions in a flexible arteriovenous fistula with an artery wall thickness greater than that of the vein. Through the reconstruction and treatment of the DICOM files, fabrication of the flexible AVF, adaptation of the experimental workbench and experimental procedures of the AVF, it will be possible to analyze the experimental data. The collected data were analyzed trying to establish a relationship between the pathological regions and the values in the pressure points collected from the system. Finally, it can be concluded that a wall thickness of 1 mm in the venous segment caused a pressure recovery in this segment and a high loss of load located in the region of the anastomosis was observed.pt_BR
dc.identifier.citationLIMA, Everton Guedes de. Fluid dynamic study in a flexible arteriovenous fistula model. 2022. 9 f. Trabalho de Conclusão de Curso (Graduação em Engenharia Mecânica) - Centro de Tecnologia, Universidade Federal do Rio Grande do Norte, Natal, 2022.pt_BR
dc.identifier.urihttps://repositorio.ufrn.br/handle/123456789/50141
dc.languageenpt_BR
dc.publisherUniversidade Federal do Rio Grande do Nortept_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Tecnologiapt_BR
dc.publisher.initialsUFRNpt_BR
dc.publisher.programEngenharia Mecânicapt_BR
dc.subjectPressurept_BR
dc.subjectFlow ratept_BR
dc.subjectWall thicknesspt_BR
dc.subjectDeformationpt_BR
dc.subjectAVFpt_BR
dc.titleFluid dynamic study in a flexible arteriovenous fistula modelpt_BR
dc.typebachelorThesispt_BR

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
FLUID DYNAMIC STUDY IN A FLEXIBLE ARTERIOVENOUS FISTULA-com ATA (1).pdf
Tamanho:
873.24 KB
Formato:
Adobe Portable Document Format
Nenhuma Miniatura disponível
Baixar

Licença do Pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.45 KB
Formato:
Item-specific license agreed upon to submission
Nenhuma Miniatura disponível
Baixar