Osseointegration evaluation of plasma nitrided titanium implants

dc.contributor.authorGuerra Neto, Custódio Leopoldino de Brito
dc.contributor.authorSilva, Marco Aurélio Medeiros da
dc.contributor.authorAlves Júnior, Clodomiro
dc.date.accessioned2020-07-14T23:19:36Z
dc.date.available2020-07-14T23:19:36Z
dc.date.issued2009
dc.description.resumoThere is a need for new techniques that modify metallic implant surfaces, resulting in good bone response for low density areas. Among the different techniques, plasma nitriding is being applied in biomedicine with excellent results. However, its use in titanium dental implants is very limited owing to high process temperatures (between 700 and 800°C) that result in distortions. In order to solve this problem, the authors used a new plasma method with a hollow cathode discharge configuration. Ti grade II dental implants were nitrided in a 20% N2–H2 atmosphere at a temperature of 450°C, 150 Pa (1·5 mbar), for 1 h and inserted into rabbit tibias to assess osseointegration. The results showed that plasma nitriding caused a significant change in the surface texture of the nitrided implants and greater removal torque than that of the control implantspt_BR
dc.identifier.citationGUERRA NETO, C. L. B.; SILVA, M. A. M. ; ALVES JUNIOR, C.. Osseointegration evaluation of plasma nitrided titanium implants. Surface Engineering, v. 25, p. 434-439, 2009. Disponível em: https://www.tandfonline.com/doi/abs/10.1179/174329409X389272. Acesso em: 13 jul. 2020. https://doi.org/10.1179/174329409X389272pt_BR
dc.identifier.doi10.1179/174329409X389272
dc.identifier.issn0267-0844
dc.identifier.urihttps://repositorio.ufrn.br/jspui/handle/123456789/29625
dc.languageenpt_BR
dc.publisherSurface Engineeringpt_BR
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Brazil*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/br/*
dc.subjectOsseointegrationpt_BR
dc.subjectDental implantspt_BR
dc.subjectSurface modificationspt_BR
dc.subjectPlasma nitridingpt_BR
dc.subjectBiomaterialspt_BR
dc.titleOsseointegration evaluation of plasma nitrided titanium implantspt_BR
dc.typearticlept_BR

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
OsseointegrationEvaluationOfPlasma_GuerraNeto_2009.pdf
Tamanho:
805.71 KB
Formato:
Adobe Portable Document Format
Carregando...
Imagem de Miniatura
Baixar

Licença do Pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.45 KB
Formato:
Item-specific license agreed upon to submission
Nenhuma Miniatura disponível
Baixar