Analysis of the pressure field in rigid arteriovenous fistula with variation in the area of the anastomosis

dc.contributor.advisorBessa, Kleiber Lima de
dc.contributor.authorSantos, Alexsandra Tome dos
dc.contributor.referees1Santos, Willyam Brito de Almeida
dc.contributor.referees2Rangel, Jonhattan Ferreira
dc.date.accessioned2022-12-14T11:59:43Z
dc.date.available2022-12-14T11:59:43Z
dc.date.issued2022-11-22
dc.description.resumoIn recent years, the number of patients with chronic renal failure (CRF) has increased. For the treatment of these patients, hemodialysis is performed. Arteriovenous fistula (AVF) is an access that provides continuous and longterm treatment, however, failure in maturation of the AVF and thrombosis in mature fistulas has been the main cause of morbidity and mortality in hemodialysis patients. This work aims to analyze the pressure field in a rigid wall arteriovenous fistula with variation in the anastomotic area, trying to establish a relationship between pathological regions and pressure values. From the computational modeling and 3D printing, three AVFs were made with variation in the anastomotic area, the anastomosis width (W) was fixed at 4 mm while the anastomosis length value (L) was varied by 5 mm, 6 mm and 7 mm, resulting in a cross-sectional area (AST) of 15.7 mm², 18.8 mm² and 22.0 mm² respectively. From the results obtained, it was observed that the variation in the size of the anastomosis considerably influences the pressures downstream of the anastomosis, with greater energy dissipation the shorter the anastomosis length.pt_BR
dc.identifier.citationSANTOS, Alexsandra Tome dos .Analysis of the pressure field in rigid arteriovenous fistula with variation in the area of the anastomosis. 2022. 8 f. Trabalho de Conclusão de Curso (Graduação em Engenharia Mecânica) - Centro de Tecnologia, Universidade Federal do Rio Grande do Norte, Natal, 2022.pt_BR
dc.identifier.urihttps://repositorio.ufrn.br/handle/123456789/50140
dc.languageenpt_BR
dc.publisherUniversidade Federal do Rio Grande do Nortept_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Tecnologiapt_BR
dc.publisher.initialsUFRNpt_BR
dc.publisher.programEngenharia Mecânicapt_BR
dc.subjectFAVpt_BR
dc.subjectAnastomotic widthpt_BR
dc.subjectAnastomotic lengthpt_BR
dc.subjectEnergy dissipationpt_BR
dc.subjectPressure droppt_BR
dc.titleAnalysis of the pressure field in rigid arteriovenous fistula with variation in the area of the anastomosispt_BR
dc.typebachelorThesispt_BR

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
ANALYSIS OF THE PRESSURE FIELD IN RIGID ARTERIOVENOUS FISTULA WITH VARIATION IN THE AREA OF THE ANASTOMOSIS -com ATA (1).pdf
Tamanho:
765.63 KB
Formato:
Adobe Portable Document Format
Nenhuma Miniatura disponível
Baixar

Licença do Pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.45 KB
Formato:
Item-specific license agreed upon to submission
Nenhuma Miniatura disponível
Baixar