Live endothelial cells on plasma-nitrided and oxidized titanium: an approach for evaluating biocompatibility

dc.contributor.authorBraz, Janine Karla França da Silva
dc.contributor.authorMartins, Gabriel Moura
dc.contributor.authorMorales, Nicole
dc.contributor.authorNaulin, Pamela
dc.contributor.authorFuentes, Christian
dc.contributor.authorBarrera, Nelson P.
dc.contributor.authorVitoriano, Jussier de Oliveira
dc.contributor.authorRocha, Hugo Alexandre de Oliveira
dc.contributor.authorOliveira, Moacir F.
dc.contributor.authorAlves Júnior, Clodomiro
dc.contributor.authorMoura, Carlos Eduardo B.
dc.date.accessioned2020-12-28T16:16:49Z
dc.date.available2020-12-28T16:16:49Z
dc.date.issued2020-04-23
dc.description.resumoWe evaluated the effects of titanium plasma nitriding and oxidation on live endothelial cell viscoelasticity. For this, mechanically polished titanium surfaces and two surfaces treated by planar cathode discharge in nitriding (36N2 and 24H2) and oxidant (36O2 and 24H2). Surfaces were characterized regarding wettability, roughness and chemical composition. Rabbit aortic endothelial cells (RAECs) were cultured on the titanium surfaces. Cell morphology, viability and viscoelasticity were evaluated by scanning electron microscopy (SEM), methyl thiazolyl tetrazolium (MTT) assay and atomic force microscopy (AFM), respectively. Grazing Incidence X-ray Diffraction confirmed the presence of TiN0,26 on the surface (grazing angle theta 1°) of the nitrided samples, decreasing with depth. On the oxidized surface had the formation of TiO3 on the material surface (Theta 1°) and in the deeper layers was noted, with a marked presence of Ti (Theta 3°). Both plasma treatments increased surface roughness and they are hydrophilic (angle < 90°). However, oxidation led to a more hydrophilic titanium surface (66.59° ± 3.65 vs. 76.88° ± 2.68; p = 0.001) due to titanium oxide films in their stoichiometric varieties (Ti3O, TiO2, Ti6O), especially Ti3O. Despite focal adhesion on the surfaces, viability was different after 24 h, as cell viability on the oxidized surface was higher than on the nitrided surface (9.1 × 103 vs. 4.5 × 103cells; p < 0.05). This can be explained by analyzing the viscoelastic property of the cellular cytoskeleton (nuclear and peripheral) by AFM. Surface oxidation significantly increased RAECs viscoelasticity at cell periphery, in comparison to the nucleus (2.36 ± 0.3 vs. 1.5 ± 0.4; p < 0.05), and to the RAECs periphery in contact with nitrided surfaces (1.36 ± 0.7; p < 0.05) and polished surfaces (1.55 ± 0.6; p < 0.05). Taken together, our results have shown that titanium plasma treatment directly increased cell viscoelasticity via surface oxidation, and this mechanobiological property subsequently increased biocompatibility.pt_BR
dc.identifier.citationBRAZ, Janine Karla França da Silva; MARTINS, Gabriel Moura; MORALES, Nicole; NAULIN, Pamela; FUENTES, Christian; BARRERA, Nelson P.; VITORIANO, Jussier O.; ROCHA, Hugo Alexandre de Oliveira; OLIVEIRA, Moacir F.; ALVES JÚNIOR, Clodomiro. Live endothelial cells on plasma-nitrided and oxidized titanium: an approach for evaluating biocompatibility. Materials Science And Engineering: C, [s. l.], v. 113, ago. 2020. Elsevier BV. 111014. Disponível em: https://www.sciencedirect.com/science/article/abs/pii/S0928493119345862?via%3Dihub#!. Acesso em: 03 set. 2020. http://dx.doi.org/10.1016/j.msec.2020.pt_BR
dc.identifier.issn0928-4931 (print)
dc.identifier.urihttps://repositorio.ufrn.br/handle/123456789/31129
dc.languageenpt_BR
dc.publisherElsevierpt_BR
dc.rightsAttribution 3.0 Brazil*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/br/*
dc.subjectImplantspt_BR
dc.subjectNitridingpt_BR
dc.subjectOxidationpt_BR
dc.subjectBiocompatibilitypt_BR
dc.subjectViscoelastic propertiespt_BR
dc.titleLive endothelial cells on plasma-nitrided and oxidized titanium: an approach for evaluating biocompatibilitypt_BR
dc.typearticlept_BR

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
LiveEndothelialCells_Braz_2020.pdf
Tamanho:
5.9 MB
Formato:
Adobe Portable Document Format
Carregando...
Imagem de Miniatura
Baixar

Licença do Pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.45 KB
Formato:
Item-specific license agreed upon to submission
Nenhuma Miniatura disponível
Baixar